Ingyenes szállítás a Packetával, 19 990 Ft feletti vásárlás esetén
Posta 1 795 Ft DPD 1 995 Ft PostaPont / Csomagautomata 1 690 Ft Postán 1 690 Ft GLS futár 1 590 Ft Packeta 990 Ft

A hyperboxing Pareto approximation method applied to radiofrequency ablation treatment planning.

Nyelv AngolAngol
Könyv Puha kötésű
Könyv A hyperboxing Pareto approximation method applied to radiofrequency ablation treatment planning. Katrin Teichert
Libristo kód: 09035682
Kiadó Fraunhofer Verlag, október 2014
Radiofrequency ablation (RFA) is a procedure to treat tumors of the liver by passing current through... Teljes leírás
? points 114 b
18 797 Ft -4 %
17 861 Ft
50 % esély Keressük az egész világon Mikor kapom meg a terméket?

30 nap a termék visszaküldésére


Ezt is ajánljuk


toplistás
Be Here Now Ram Dass / Puha kötésű
common.buy 7 717 Ft
The LT Spice XVII Simulator Würth Elektronik / Kemény kötésű
common.buy 16 125 Ft
Noticer Andy Andrews / Puha kötésű
common.buy 6 377 Ft
How to Read People Like a Book James W. Williams / Puha kötésű
common.buy 8 858 Ft
Lost Fleet Jack Campbell / Puha kötésű
common.buy 4 591 Ft
Lost Fleet Jack Campbell / Puha kötésű
common.buy 3 721 Ft
Raven Flight Juliet Marillier / Puha kötésű
common.buy 6 077 Ft
Figure It Out Karl Fast / Puha kötésű
common.buy 14 815 Ft
3D Virtual Treatment Planning of Orthognathic Surgery Gwen Swennen / Kemény kötésű
common.buy 85 502 Ft
Smart Grid Planning and Implementation CLARK GELLINGS / Kemény kötésű
common.buy 74 423 Ft
Affordances for Teaching in an International Classroom Gaisch Martina / Puha kötésű
common.buy 42 673 Ft
Warning I C Sawusch-Pytlik / Puha kötésű
common.buy 4 656 Ft
Southern Boy Armiger Jagoe / Puha kötésű
common.buy 6 407 Ft
The Christocentricity of the Virtues in St. Bonaventure Stephen Marques Matuszak / Puha kötésű
common.buy 18 576 Ft
Among the Ten Thousand Things Julia Pierpont / Puha kötésű
common.buy 4 156 Ft

Radiofrequency ablation (RFA) is a procedure to treat tumors of the liver by passing current through a needle shaped applicator placed inside the tumor. The tissue gets heated up and tumor cells are destroyed. Careful planning of the applicator positioning is mandatory for a successful treatment. The desirability of a specific applicator positioning is measured by different criteria, rendering the RFA planning problem a multi-objective optimization problem. In our work we propose a deterministic vector optimization approach to solve the multi-objective RFA treatment planning problem. To allow for numerical optimization routines, feasibility must be expressed as a set of constraint functions. A difficult-to-treat aspect of feasibility is non-overlapping with critical structures such as organs and bones. We propose a modelling approach where the critical structures are approximated as a set of convex polytopes. Then it is a well-known fact that the non-overlapping condition is equivalent to the existence of a set of separating planes -- each plane separating the applicator from one of the polytopes. In this way we can express the non-overlapping condition as a set of analytical constraint functions. A vector optimization approach strives to represent or approximate the set of efficient solutions. In this work we develop the adapted hyperboxing algorithm as a specific sandwiching method for the approximation of a non-convex non-dominated set. As in similar approaches, the non-dominated set is enclosed by a set of boxes, whose size is reduced systematically in the course of the algorithm. The adapted hyperboxing algorithm differs from previous methods in the construction of these boxes, which are spanned by the set of all feasible combinations of a so-called inner and an outer knee point. For the bi-criteria case we prove an a-priori upper bound for the approximation quality achieved by this algorithm. We show with several examples that the developed method can be successfully applied to calculate the non-dominated set of real-data RFA planning problems.

Információ a könyvről

Teljes megnevezés A hyperboxing Pareto approximation method applied to radiofrequency ablation treatment planning.
Szerző Katrin Teichert
Nyelv Angol
Kötés Könyv - Puha kötésű
Kiadás éve 2014
Oldalszám 145
EAN 9783839607831
ISBN 3839607833
Libristo kód 09035682
Súly 221
Méretek 146 x 210 x 10
Ajándékozza oda ezt a könyvet még ma
Nagyon egyszerű
1 Tegye a kosárba könyvet, és válassza ki a kiszállítás ajándékként opciót 2 Rögtön küldjük Önnek az utalványt 3 A könyv megérkezik a megajándékozott címére

Belépés

Bejelentkezés a saját fiókba. Még nincs Libristo fiókja? Hozza létre most!

 
kötelező
kötelező

Nincs fiókja? Szerezze meg a Libristo fiók kedvezményeit!

A Libristo fióknak köszönhetően mindent a felügyelete alatt tarthat.

Libristo fiók létrehozása