Ingyenes szállítás a Packetával, 19 990 Ft feletti vásárlás esetén
Posta 1 795 Ft DPD 1 995 Ft PostaPont / Csomagautomata 1 690 Ft Postán 1 690 Ft GLS futár 1 590 Ft Packeta 990 Ft

Inductively Coupled Resonant Humidity Monitoring Exploiting Irreversible State Changes

Nyelv AngolAngol
Könyv Puha kötésű
Könyv Inductively Coupled Resonant Humidity Monitoring Exploiting Irreversible State Changes Sebastian Sauer
Libristo kód: 15210857
Kiadó Books on Demand, szeptember 2016
Due to the pervasive nature of water, water vapor, and moisture, there is a strong influence on the... Teljes leírás
? points 210 b
32 953 Ft
Beszállítói készleten Küldés 14-18 napon belül

30 nap a termék visszaküldésére

Due to the pervasive nature of water, water vapor, and moisture, there is a strong influence on the product quality of a multitude of goods (e.g., food, chemicals, electronics, ammunition, etc.). Humidity as environmental water vapor is therefore of strong interest for the purposes of measurement and control throughout the life cycle of goods not only in regard to their use but also during manufacture, transport, and storage. One of the key requirements of monitoring measurement systems is to determine critical threshold or accumulated dosage exposure conditions. Nowadays, RFID technology is established, and a large number of standardized and non-standardized solutions of differing complexity exist. Sensor-enhanced RFID tags not only provide unique identification information but also additional sensor information. Fulfilling a monitoring task on item level is challenging when there is no continuous supply of electric energy available, a common application constraint in sensor-enhanced RFID applications. Application constraints are impeded due to the low cost requirements on the RFID market. Wireless passive humidity monitoring sensor solutions, in which the exceedance of a humidity threshold leads to a permanent, preferably irreversible change of a sensor parameter are proposed in this study. In the presented solutions, this is either a lasting electric resistance (IREV-R sensor approach) or an electric capacitance change (IREV-C sensor approach). For this purpose a number of physico-chemical phenomena are technically exploited in different sensor arrangements. These are the deliquescence of salts as threshold detection mechanism, transport processes in porous media as well as chemical liquid phase sintering of metal nanoparticles. The sensor principles introduced effectively act as humidity threshold-activated relative humidity dosimeters. For use in combination with RFID tags single use, low-cost sensor solutions are favored. Inkjet print as a representative mass production technique for printed electronics is examined in more depth, and its application exemplified for the IREV-R sensor principle. Theoretical, numerical and laboratory experimental results, which demonstrate the feasibility of the proposed sensor principles and developed solutions, are presented.

Információ a könyvről

Teljes megnevezés Inductively Coupled Resonant Humidity Monitoring Exploiting Irreversible State Changes
Szerző Sebastian Sauer
Nyelv Angol
Kötés Könyv - Puha kötésű
Kiadás éve 2016
Oldalszám 206
EAN 9783741274305
ISBN 3741274305
Libristo kód 15210857
Súly 277
Méretek 148 x 210 x 12
Ajándékozza oda ezt a könyvet még ma
Nagyon egyszerű
1 Tegye a kosárba könyvet, és válassza ki a kiszállítás ajándékként opciót 2 Rögtön küldjük Önnek az utalványt 3 A könyv megérkezik a megajándékozott címére

Belépés

Bejelentkezés a saját fiókba. Még nincs Libristo fiókja? Hozza létre most!

 
kötelező
kötelező

Nincs fiókja? Szerezze meg a Libristo fiók kedvezményeit!

A Libristo fióknak köszönhetően mindent a felügyelete alatt tarthat.

Libristo fiók létrehozása