Ingyenes szállítás a Packetával, 19 990 Ft feletti vásárlás esetén
Posta 1 795 Ft DPD 1 995 Ft PostaPont / Csomagautomata 1 690 Ft Postán 1 690 Ft GLS futár 1 590 Ft Packeta 990 Ft

Electrical Resistivity subsurface survey

Nyelv AngolAngol
Könyv Puha kötésű
Könyv Electrical Resistivity subsurface survey Nafiu Sadq Aliyu
Libristo kód: 02201456
Kiadó LAP Lambert Academic Publishing, október 2013
The type of method adopted for this research was 1D electrical resistivity, using the Geopulse Tarra... Teljes leírás
? points 131 b
22 483 Ft -9 %
20 307 Ft
Beszállítói készleten Küldés 8-10 napon belül

30 nap a termék visszaküldésére


Ezt is ajánljuk


Ein neuer Anfang Esther Hicks / Puha kötésű
common.buy 4 009 Ft
Kenneth Boulding Robert Scott / Kemény kötésű
common.buy 51 477 Ft
Plantagenet Empire 1154-1224 Martin Aurell / Puha kötésű
common.buy 26 430 Ft
Preguem de la A a la Z Juanjo Fernández Sola / Puha kötésű
common.buy 5 143 Ft
Salam Mirjam Michael Landgraf / Kemény kötésű
common.buy 6 694 Ft
Kaite Woo: The Best Club Fran Manushkin / Puha kötésű
common.buy 3 263 Ft
Lena Roswitha Gruber / Kemény kötésű
common.buy 6 679 Ft
Beethovens Briefe Karl Storck / Puha kötésű
common.buy 13 876 Ft
Modern Electrical Drives H. Bülent Ertan / Puha kötésű
common.buy 152 923 Ft
Fashhion-Plus Knits LEISURE ARTS / Puha kötésű
common.buy 4 133 Ft
Audience Transformations Nico Carpentier / Kemény kötésű
common.buy 80 358 Ft
Florante Francisco Balagtas / Kemény kötésű
common.buy 20 198 Ft

The type of method adopted for this research was 1D electrical resistivity, using the Geopulse Tarrameter. A schlumberger configuration was carried out to map out the geological features of the Earth subsurface. Five profiles were carried out in the study area, each profile, the layout geometry for the electrical survey were the normal schlumberger arrays. The maximum current electrode seperation (AB) was 200m i.e AB/2=100m. Based on the electrical resistivity value obtained in the study area, the following deduction were made: The average depth to the fresh basement is generally beyond 30m, the study revealed the presence of two distinct layers, the top soil and weathered basement with resistivity range of 20-782 ohm-meter and 100-978ohm-meter respectively. The overburden with a thickness of 18m and this is a good aquifer in the study area.

Információ a könyvről

Teljes megnevezés Electrical Resistivity subsurface survey
Nyelv Angol
Kötés Könyv - Puha kötésű
Kiadás éve 2013
Oldalszám 96
EAN 9783659431746
Libristo kód 02201456
Súly 161
Méretek 150 x 220 x 6
Ajándékozza oda ezt a könyvet még ma
Nagyon egyszerű
1 Tegye a kosárba könyvet, és válassza ki a kiszállítás ajándékként opciót 2 Rögtön küldjük Önnek az utalványt 3 A könyv megérkezik a megajándékozott címére

Belépés

Bejelentkezés a saját fiókba. Még nincs Libristo fiókja? Hozza létre most!

 
kötelező
kötelező

Nincs fiókja? Szerezze meg a Libristo fiók kedvezményeit!

A Libristo fióknak köszönhetően mindent a felügyelete alatt tarthat.

Libristo fiók létrehozása