Ingyenes szállítás a Packetával, 19 990 Ft feletti vásárlás esetén
Posta 1 795 Ft DPD 1 995 Ft PostaPont / Csomagautomata 1 690 Ft Postán 1 690 Ft GLS futár 1 590 Ft Packeta 990 Ft

Balancing Exhaust Ventilation Systems

Nyelv AngolAngol
Könyv Puha kötésű
Könyv Balancing Exhaust Ventilation Systems Vivek Balasubramanian
Libristo kód: 06820851
Kiadó VDM Verlag Dr. Müller, november 2008
Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §c... Teljes leírás
? points 124 b
20 489 Ft -4 %
19 470 Ft
Kiadói készleten rendelésre Küldés 3-5 napon belül

30 nap a termék visszaküldésére


Ezt is ajánljuk


Hot Vegan Robin Robertson / Puha kötésű
common.buy 6 664 Ft
Thirteen Albatrosses DONALD HARINGTON / Puha kötésű
common.buy 6 303 Ft
In absentia [Judici a la Terra] Jordi Ortiz / Puha kötésű
common.buy 4 481 Ft
Industrial Power Systems Sheeba Khan / Kemény kötésű
common.buy 118 907 Ft
Sound Pulses F. G. Friedlander / Puha kötésű
common.buy 19 706 Ft
Absurdist Angles on History Merritt Abrash / Puha kötésű
common.buy 7 979 Ft
Affine Ebenen Artur Bergmann / Puha kötésű
common.buy 56 137 Ft

Dampers are used to adjust the distribution of §airflows in duct systems. The common (i.e., most §commonly used) method is to adjust each damper in §turn so that the airflow through its branch equals §the desired level. Typically, the airflow through §each branch duct is estimated from the centerline §velocity pressure. To test the effectiveness of that §approach, dampers were adjusted on a seven branch, §full-sized experimental duct system. After adjusting §the dampers for a given condition, the percent §excess airflow (%Qexcess) for the system was §estimated as the amount above the ideal fan airflow §that would exist if the fan speed were adjusted so §that the lowest ratio of airflow to airflow goal for §any branch was unity. The lower the value of percent §excess airflow, the more perfectly balanced the §system was. The results varied with the level of the §target airflows. The excess airflow values were much §higher than the airflow values found by Dodrill §(2004) on the same system for the SPh Goal Ratio §method proposed by Guffey (2005). This analysis §should be useful to professionals in the fields of §HVAC and ventilation design.

Információ a könyvről

Teljes megnevezés Balancing Exhaust Ventilation Systems
Nyelv Angol
Kötés Könyv - Puha kötésű
Kiadás éve 2009
Oldalszám 72
EAN 9783639120301
Libristo kód 06820851
Súly 124
Méretek 150 x 220 x 4
Ajándékozza oda ezt a könyvet még ma
Nagyon egyszerű
1 Tegye a kosárba könyvet, és válassza ki a kiszállítás ajándékként opciót 2 Rögtön küldjük Önnek az utalványt 3 A könyv megérkezik a megajándékozott címére

Belépés

Bejelentkezés a saját fiókba. Még nincs Libristo fiókja? Hozza létre most!

 
kötelező
kötelező

Nincs fiókja? Szerezze meg a Libristo fiók kedvezményeit!

A Libristo fióknak köszönhetően mindent a felügyelete alatt tarthat.

Libristo fiók létrehozása